by Jeff Atkins on November 13, 2026

What Wire Is Used for Keypads and Card Readers?

Keypads and card readers are common parts of access control and security systems, but there is not one universal cable that works for every device.

The right wire depends on what the keypad or reader needs to carry. Some devices only need low voltage power and basic control connections, while others require separate conductors for data, LEDs, buzzers, tamper circuits, or other functions.

The communication method matters too. A traditional Wiegand card reader and a modern OSDP reader may have different cabling requirements, especially when twisted pair communication is involved.

This guide explains the types of cable commonly used for keypads and card readers, including 22/4 alarm wire, combination power and control cable, and composite access control cable.

What Wire Is Commonly Used for Keypads and Card Readers?

22 AWG control and alarm cable is commonly used for many keypad and reader signal circuits. Larger conductors such as 18 AWG or 16 AWG may be used when more power needs to be delivered or when voltage drop becomes more important.

For more complex access control installations, combination and composite cables can place power, communication, door contact, lock, and other conductors into one overall cable, helping simplify installation.

Start With the Device Requirements

Before selecting cable, check the keypad or card reader manufacturer's wiring diagram.

The device may require connections for:

  • Positive DC power
  • Ground or DC return
  • Reader data
  • LED control
  • Beeper control
  • Tamper monitoring
  • Keypad communication
  • RS-485 communication

The number of conductors, conductor gauge, shielding, twisted pair construction, and maximum cable distance can vary by system.

Using 22/4 Alarm Wire for Keypads

For many simpler keypad and control applications, four conductor 22 AWG cable can be a practical option when the device manufacturer calls for four low voltage conductors.

Infinity Cable Products 22/4 Stranded Alarm Wire contains four stranded 22 AWG 100% bare copper conductors and is designed for low voltage security applications including keypads, alarm panels, access control systems, motion detectors, door contacts, and other control devices.

The stranded construction makes the cable flexible and easier to route through walls, around corners, and into device boxes.

22/4 can be a good choice when the device only needs a small number of low current control connections, but it should not automatically be used for every card reader or every access control circuit.

When 22/4 May Not Be Enough

A card reader may need more than four conductors, particularly with legacy Wiegand systems.

A basic Wiegand reader may use separate conductors for:

  • Power
  • Ground
  • Data 0
  • Data 1
  • LED control
  • Beeper control
  • Additional device functions

Because of this, conductor count should always be verified before cable is installed.

Wiegand vs OSDP Reader Wiring

Two common reader communication methods are Wiegand and OSDP.

Wiegand is a legacy point to point interface that typically uses multiple dedicated conductors between the reader and access control panel.

OSDP uses RS-485 communication, which typically relies on a twisted pair for data along with separate conductors for power.

For OSDP, it is important to think of the cable as having two different functions:

  • Power conductors for the reader
  • A properly selected twisted pair for RS-485 communication

This is where combination automation and control cables can become useful.

22/2 + 18/2 Automation and Control Cable

For installations that need both device power and a shielded communication pair, Infinity Cable Products offers 22/2 + 18/2 CMP Plenum Automation Cable.

This cable combines:

  • Two 18 AWG power conductors
  • One shielded 22 AWG twisted pair

The larger 18 AWG conductors can handle the power portion of the run, while the shielded 22 AWG twisted pair can carry communication or control signals when compatible with the equipment.

This construction can be useful in access control, security, smart building, and other automation installations where one device needs both power and data.

The CMP version is intended for plenum and in wall installations where a plenum rated cable is required.

22/2 + 18/2 CMR Riser Automation Cable

For installations that do not require a plenum jacket, Infinity Cable Products also offers a 22/2 + 18/2 CMR Riser Automation Cable.

It uses the same general construction concept:

  • Two 18 AWG power conductors
  • One shielded 22 AWG twisted pair

The main difference is the jacket rating. The CMR version is designed for riser and general in wall installations rather than plenum air handling spaces.

This makes it a useful option when an access control or automation device needs power plus a protected signal pair, but the cable pathway does not require CMP.

22/2 + 16/2 Automation and Control Cable

For installations where even lower resistance is preferred on the power conductors, Infinity Cable Products also offers combination cable using 16 AWG power conductors.

The 22/2 + 16/2 CMP Plenum Automation/Control Cable combines:

  • Two 16 AWG power conductors
  • One shielded 22 AWG twisted pair

The larger 16 AWG power conductors have lower resistance than 18 AWG, which can be useful when the power run is longer or the connected equipment requires more current.

The shielded 22 AWG pair is kept separate for communication or control signals.

This cable is CMP rated for plenum applications.

22/2 + 16/2 CMR Riser Automation + Control Cable

A riser rated version is also available.

The 22/2 + 16/2 CMR Riser Automation/Control Cable combines two 16 AWG power conductors with a shielded 22 AWG twisted pair.

This gives installers a similar power and data layout while using a CMR jacket for appropriate riser and in wall pathways.

Why Use a Combination Power and Data Cable?

Combination cables can simplify installations where the same device needs both low voltage power and communication wiring.

Instead of pulling a power cable and a separate communication cable, one overall cable can contain both conductor groups.

This can help:

  • Reduce the number of separate cable pulls
  • Keep related conductors together
  • Simplify pathway organization
  • Reduce cable congestion
  • Make installation and troubleshooting easier

The correct combination still depends on the device specifications, especially the required communication protocol and conductor size.

ACT-P-YE-500 Composite Access Control Cable

For a complete controlled opening, a simple four conductor or power plus data cable may not be enough.

A door may include several devices at once, such as:

  • Card reader
  • Keypad
  • Electric strike or magnetic lock
  • Door contact
  • Request to exit device
  • Other security or monitoring equipment

For these applications, Infinity Cable Products offers ACT-P-YE-500 Access Control Cable.

This composite cable combines multiple conductor groups under one overall jacket:

  • 18 AWG x 4 conductors
  • 22 AWG x 3 shielded pairs
  • 22 AWG x 2 conductors
  • 22 AWG x 4 conductors

Instead of pulling multiple completely separate cables to the same controlled opening, the composite construction allows several access control functions to travel together in one overall cable.

This can be especially useful on professional commercial access control projects where a door includes multiple devices and circuits.

What Can the Different Conductor Groups Be Used For?

The exact assignment should follow the system design, but different conductor groups in a composite cable can support different parts of the controlled opening.

For example, larger 18 AWG conductors may be useful for circuits requiring more power, while the smaller 22 AWG conductor groups may be used for reader communication, contacts, request to exit devices, or other control functions.

The shielded pairs can help support sensitive communication circuits when shielding and twisted pair construction are required.

The major benefit is that the installer has several conductor types available in one overall cable instead of having to pull each cable separately.

Why 18 AWG and 16 AWG Are Used for Power

Power conductors often need to be larger than signal conductors because they carry more current.

As conductor size increases, electrical resistance decreases.

This means 18 AWG has lower resistance than 22 AWG, while 16 AWG has lower resistance than 18 AWG.

Lower resistance can help reduce voltage drop over longer runs.

Whether 18 AWG or 16 AWG is needed depends on:

  • Device current
  • Power supply voltage
  • Cable distance
  • Acceptable voltage drop
  • Terminal size
  • Manufacturer requirements

Why Use Shielded Twisted Pair for Communication?

Some access control and automation systems use balanced communication methods such as RS-485.

Twisting the communication conductors together helps reduce the effects of electromagnetic interference.

Shielding can provide another layer of protection in electrically noisy environments when the equipment manufacturer calls for it.

This is why cables such as the 22/2 + 18/2 and 22/2 + 16/2 automation cables separate the power conductors from a shielded 22 AWG twisted data pair.

Do All Card Readers Need Shielded Cable?

No. Shielding requirements depend on the reader, communication protocol, distance, surrounding electrical environment, and manufacturer specifications.

It is better to select cable based on the actual reader and controller combination rather than assuming every card reader requires the same construction.

What About Door Contacts?

A basic door contact is normally much simpler than a card reader.

Many door contact circuits only require two low voltage conductors.

For these applications, products such as 22/2 Stranded Alarm Wire may be appropriate when the system design permits it.

When a door contact is part of a larger controlled opening, the necessary contact conductors may already be included within a composite access control cable such as ACT-P-YE-500.

What About Plenum and Riser Ratings?

The conductor configuration is only part of choosing the correct cable.

The jacket rating must also match the installation pathway.

CMP plenum cable is intended for appropriate environmental air handling and plenum spaces.

CMR riser cable is designed for appropriate riser and general in wall installations but is not automatically suitable for a plenum pathway.

This is why Infinity Cable Products offers both CMP and CMR versions of several automation and control cables.

Common Keypad and Card Reader Wiring Mistakes

  • Assuming every keypad and reader uses the same cable
  • Assuming four conductors are enough for every Wiegand reader
  • Ignoring twisted pair requirements for RS-485 communication
  • Using 22 AWG for a higher current power circuit without checking voltage drop
  • Ignoring the difference between CMP and CMR cable
  • Pulling multiple separate cables when a combination or composite cable would simplify the installation
  • Assuming shielding is required for every reader
  • Choosing cable before checking the reader or controller wiring diagram
  • Ignoring device terminal size and compatibility

How to Choose the Right Cable

Before pulling cable to a keypad, card reader, or controlled door, check:

  1. What type of device is being connected?
  2. Does it use Wiegand, OSDP, RS-485, or another communication method?
  3. How many conductors are required?
  4. Does the communication circuit need twisted pair?
  5. Does it require shielding?
  6. How much current does the device require?
  7. How far is it from the power source or controller?
  8. Would 18 AWG or 16 AWG power conductors reduce voltage drop?
  9. Does the cable pathway require CMP or CMR?
  10. Would a combination or composite cable simplify the project?

Quick Recommendation

For a simple keypad or basic low voltage control device, 22/4 copper alarm wire may be a practical choice when the device requires four conductors.

If the device needs both power and a twisted communication pair, a 22/2 + 18/2 or 22/2 + 16/2 automation/control cable may provide a cleaner one cable solution.

For a complete access control door with a reader, lock, contact, request to exit device, and other circuits, ACT-P-YE-500 composite access control cable provides multiple conductor groups in a single overall cable.

Frequently Asked Questions

Can you use 22/4 wire for a keypad?

Yes. 22/4 copper alarm wire can work for many low voltage keypads when the device requires four conductors and the gauge, distance, current, and cable rating meet the manufacturer's requirements.

Can you use 22/4 wire for a card reader?

Sometimes, but not universally. Wiegand readers may require more than four conductors, while OSDP readers typically use power conductors plus a twisted pair for communication.

What is 22/2 + 18/2 automation cable used for?

This cable combines two 18 AWG power conductors with a shielded 22 AWG twisted pair, allowing low voltage power and communication to be carried in one overall cable for compatible access control, security, and automation devices.

When would you use 22/2 + 16/2 cable?

The 16 AWG version may be useful when lower resistance is preferred on the power conductors, such as longer runs or applications with higher current requirements.

What is composite access control cable?

Composite access control cable combines several different conductor groups under one overall jacket so multiple door devices and circuits can be installed with fewer separate cable pulls.

What is ACT-P-YE-500 used for?

ACT-P-YE-500 is designed for professional access control installations where one controlled opening may include readers, locks, door contacts, request to-exit devices, and other related circuits.

Does OSDP require twisted pair?

OSDP uses RS-485 communication, so an appropriately selected twisted pair is generally used for the communication connection. Always follow the reader and controller manufacturer's cable requirements.

Do card readers require shielded cable?

Not always. Shielding requirements depend on the communication method, equipment, cable distance, and installation environment.

Should I use CMP or CMR cable?

Use the rating required by the building pathway and applicable code. CMP is used for appropriate plenum spaces, while CMR is intended for appropriate riser and general in wall installations.

The Bottom Line

There is no single cable that is best for every keypad or card reader.

22/4 alarm wire can be a practical solution for simpler keypad and control circuits.

For devices that need both power and communication, Infinity Cable Products offers combination cables using 18 AWG power + shielded 22 AWG twisted pair or 16 AWG power + shielded 22 AWG twisted pair.

For a complete controlled opening, ACT-P-YE-500 composite access-control cable combines multiple 18 AWG and 22 AWG conductor groups into one overall cable, helping simplify projects with readers, locks, contacts, request to exit devices, and other access control components.

The best approach is to review the equipment wiring diagram first, then choose the conductor count, wire gauge, twisted pair construction, shielding, and jacket rating that match the installation.